Investigation of the Spatial Variation of Soil Resistivity and Conductivity in Ajibode Area, Ibadan
Keywords:
Electrical Resistivity, Wenner electrode array, soil conductivity, sandy soil, Ajibode.Abstract
Electrical resistivity method was carried out investigate spatial variation of soil resistivity and conductivity at a certain depth in Ajibode Area using Miller 400D resistance meters. Three locations were considered with a total of 178 data points.
It was observed that the absolute value of the resistivity obtained in location one is 6428.53
References
Halvorson, A. D, and J.D Rhoades (1976) field mapping soil conductivity to delineate dry land saline seeps with four- electrode technique soil sci soc AM.J. 40:571-574
Chang, C., T.G. Sommerfeldt, J.M. Carefoot, and G.B. Schaalje. (1983). Relationships of electrical conductivity with total dissolved salts and cation concentration of sulfate-dominant soil extracts. Can. J. Soil Sci. 63:79-86. conductance of soil. Soil Sci. Soc. Am. J. 44:925-929.
Rhoades, J.D., S.M. Lesch, P.J. S house and W.J. Alves. (1989b). New calibrations for determining soil electrical conductivity-depth relations from electromagnetic measurements. Soil Sci. Soc. Am. J. 53:74 79.
Nigeria Geological Survey Agency, (1972).
Olayinka, A.I. and Olayiwola, M.A. (2001). An integrated used of geo electrical imaging and hydrogeochemical methods in delineating limits of polluted surface and groundwater at a landfill site in Ibadan area, Southwestern Nigeria. Journal of Mining and Geology. 37.1:53-68.
Nagrath, I.J and Kothari, D., (2001),