Choices to Decrease Cooling Tower Water Wastage in Fertilizer Plants (Lagging KPIs)

Authors

  • Zulfiqar Ali Dasti B.SC Chemical Engg: PhD Scholar NCBAE Lahore
  • Iftikhar Ahmad
  • Khalid Qamar
  • Faisal Raza

Keywords:

water resource Management, cooling tower, make up water, evaporation rate, blow-down, water conservation

Abstract

Water recognizes our planet gap with all the others we think about. There are numerous districts where our freshwater assets are lacking to meet natural needs and thus we all associated with inquire about discover approaches to evacuate these imperatives. We face various difficulties in doing that, particularly since 1965, the paper Water reserve Exploration has assumed a significant profession in revealing and scattering existing study. This paper recognizes the issues confronting water today and future research expected to more readily advise the individuals who endeavor to make a progressively manageable and attractive future. In fertilizer lagging key performance indicators at cooling tower water wastages addressed by experimentally to overcome the evaporation, blow-down and make-up water losses from maximum (576 ) to minimum 288 level to promote environment sustainability.

References

. Baker, D. (N.D)

. Bonger, R.(1995) “New Development in Air-curled steam condensing”

. Chang-Qin, R. (2008) “Correlation NTU method International Journal of heat transfer” 51:237-245

. Jaber, H. & Webb, R.L. (1989) “Design of cooling tower by effectiveness NTU method” 111:837-843

. Khan &Zubair (2001)

. Kloppers &Kroger (2005)

. Lewis,

. Merkel, F. (1925) VDI 70:123-128

. Nottage, H.B. (1941) “Performance correlative for air-water evaporation Cooling system ASHRE trans 47:429-448

. Pastor, E.L. (1974) “An investigation of the accuracy of the evaporation cooling tower calculations” 59-74

. Poppe, M, (1991) “Calculations of cooling process VDI” 1-15

. Prasad, M. (2003) “Economic up gradation and optimal use of mutli cell cross flow evaporative water cooling tower through modular performance appraisal” 24:579-593

. Sampson, Sherwood T.K. (1946) “performance of Small mechanical draft cooling tower” 52:535-543,574-576

. Threlkeld, J.(N.D) “thermal Environment Engineering” New Jersery.

. Zivi, S, M. (1956) “An analysis of the cross flow cooling tower” 64:31-34

Downloads

Published

2020-05-09

How to Cite

Dasti, Z. A. ., Ahmad, I. ., Qamar, K. ., & Raza, F. . (2020). Choices to Decrease Cooling Tower Water Wastage in Fertilizer Plants (Lagging KPIs). International Journal of Sciences: Basic and Applied Research (IJSBAR), 51(2), 144–162. Retrieved from https://gssrr.org/index.php/JournalOfBasicAndApplied/article/view/11136

Issue

Section

Articles